The paper synthetically discusses the methods used in operational practice for determining the reliability, availability, and failure rate indicators of power units. Against this background, a presentation was made of a computer program developed at the Institute of Electrical Power Engineering of the Lodz University of Technology, created based on the MS Access application, used to assess the reliability indicators of 370 MW units installed in the largest block power plant in the country and Europe fired by lignite – the Bełchatów Power Plant, which is part of the PGE Górnictwo i Energetyka Konwencjonalna S.A. group. The assessment was carried out based on populations of operational events collected in a computer database, which occurred on all twelve units of the power plant from the beginning of their operation until the end of 2010.
COMPUTER AIDED SYSTEM FOR ESTIMATION OF POWER UNIT RELIABILITY
W paper presents methods of estimation of power units reliability, availability and failure frequency used in operational practice. With use of MS Access environment, the computer program has been worked out in Institute of Electrical Power Engineering at Technical University of Lodz and intended for 370 MW rated power units installed in the largest lignite fired power plant in Europe, i.e. in Belchatow Power Plant.
The reliability study has been done with use of the computer database containing failure files for the dozen of power units and covering the period since power plant commissioning till 2010.
1. (…)
The article contains 17059 characters.
Source: Logistyka Magazine
Computer-aided system for assessing the reliability of power units – PDF file for download