A sudden and unexpected event resulting in negative consequences such as material losses and loss of life is a disaster. The spectacular collapse of the suspension bridge that occurred on November 7, 1940, in Tacoma in the northwestern part of the United States of America drew the attention of engineers to the importance of wind pressure on the structure as a dynamic effect that must be taken into account when designing suspension bridges.
The cause of the bridge disaster, in addition to insufficient stiffness of the spans, was also inadequate aerodynamic stability and the associated convergence of the natural frequency of vibrations of the spans and pylons, which caused resonance.
Prof. A. Jarominiak lists four main groups of causes leading to bridge disasters:
1. Material defects.
2. Defective foundations.
3. Technological errors.
4. Natural disasters.
Humans are responsible for some of these causes – we then speak of anthropogenic disasters resulting from design errors or insufficient supervision at both the design and construction stages (statistics show that only one-fifth of disasters result from insufficient material strength).
The dynamic development of computational techniques, mandatory testing of bridge structures with large spans and innovative technologies in wind tunnels, and integrated systems for monitoring the state of displacements and the distribution of internal forces have significantly improved the safety of bridge use. However, it should be emphasized that new bridge structures are only a small fragment of the road infrastructure. On a macro scale, the safety of using the communication network is determined by the technical condition of the road infrastructure, including, of course, the condition of urban and non-urban bridges, viaducts, culverts, etc.
Formal and legal foundations of the system for assessing the technical condition of public utility building structures
Conducting an inspection of the technical condition of building structures and constructions results from Art. 62 sec. 1 points 1 and 2 of the Construction Law Act (Journal of Laws of 2013, item 1409), Art. 62. 1. During their use, objects should be subjected by the owner or manager to:
– periodic inspection, at least once a year, consisting of checking the technical condition of:
a) elements of the building, structure, and installations exposed to harmful atmospheric influences and the destructive effects of factors occurring during the use of the object,
b) installations and equipment used for environmental protection,
c) gas installations and chimney flues (smoke, exhaust, and ventilation);
– periodic inspection, at least once every 5 years, consisting of checking the technical condition and suitability for use of the building structure, the aesthetics of the building structure, and its surroundings; this inspection should also include testing the electrical and lightning protection installation in terms of the efficiency of connections, equipment, protection and shock protection measures, insulation resistance of wires, and grounding of installations and apparatus.
The above-mentioned inspections may be carried out only by persons holding construction qualifications in the appropriate specialty.