Warehouse design considering fire load – a case study

Warehouse design considering fire load - a case study

Most fire safety requirements for production, warehouse, and residential buildings are related to the fire load density value present in the building or its parts. Based on this value, we can determine the fire resistance class, the size of fire zones, fire resistance requirements for structural elements, or even the relative duration of a fire.

Therefore, it is very important to correctly determine this value. On the other hand, the architectural and structural concept applied to a warehouse building may not ensure its adequate fire resistance. That is why incorporating fire safety issues into the warehouse design process is crucial.

Calculating fire load density
According to the Polish Standard regarding fire protection of buildings, “fire load density is defined as the thermal energy, expressed in megajoules, that can be generated by the combustion of combustible materials located in a room, fire zone, or solid material storage area, per unit area of that facility, expressed in square meters.” Fire load density is usually determined at the warehouse design stage. Its value is assumed after analyzing the types of substances to be stored and considering their expected quantity. During the operation of a warehouse facility, inventory levels change, so actual values must be calculated in each of the warehouse sub-zones, and then checked to see if fire load limits have been exceeded. The best solution is to use additional supporting software that continuously monitors the fire load density occurring in warehouse zones. However, if such software is not available, we must perform these calculations ourselves. When calculating, one must consider:
– the type of product packaging (paper, polypropylene, etc.)
– the stored assortment (food products, household appliances, etc.)
– the quantity of goods
– net and gross weights.
According to the Polish Standard, combustible materials submerged in water and aqueous solutions, as well as materials with a water content above 60%, are not included. There is also a group of materials whose actual masses are only included at 10%. These include, among others: carbonated and non-carbonated beverages, preserves, frozen fruit and vegetables, grain in chambers and bins, round timber with a diameter of at least 0.2 m, hard coal and coke in piles and heaps higher than 1 m. Substances whose actual masses are included at 20% are: grains, sugar, flour, groats, etc., but this does not apply to oilseeds. They are stored in bags arranged in stacks and layers. During a fire, when the bag burns through, the spilling substance will suppress the fire.

 